Mini Input Module
 


 
The FC410MIM Mini Input module is designed to monitor fire contacts, such as extinguishing system control, ventilation control, fire door control etc. The module provides one identifiable detection spur which is capable of monitoring multiple normally open contacts or a single normally closed contact.
 
The FC410MIM can be mounted in any electrical enclosure with sufficient depth to accommodate FC410MIM and the contacts monitored by the IN+ and IN- terminals, ie, no field wiring. The remote LED (if required, not supplied) must be located within the same electrical enclosure.
 
Product order code: 555.800.701
 
Contact Input Module
 


 
The FC410CIM FC Addressable Contact Input Module is designed to monitor fire contacts such as extinguishing system control, ventilation control, fire door control etc. The FC410CIM can be configured as: Two spur circuits monitoring multiple normally open contacts, with short circuit giving a fault output.
 
Two spur circuits monitoring single normally closed contacts, with short circuit giving a fault output.
 
Product order code: 555.800.702
 
Gas & Detection Module Indoor
 


 
The FC410DDM provides the ability to connect and interface 2 conventional zones, to the FireClass fire alarm controller.
 
The FC410DDM monitors the status of the detectors and the wiring to the detectors and signals detector and wiring status back to the controller.
 
The conventional detector circuits can be configured as one Class A circuit (loop) or two Class B spur circuits. The FC410DDM can be either loop powered or driven from a local 24Vdc supply.
 
It also provides the ability to connect 2 gas detectors (supported by FC500 series panels only).
 
Product order code: 577.800.706
 
Detector Input Module
 


 
The Addressable FC410DIM provides the ability to connect and Interface one zone of conventional detectors (non-addressable) to the Fire Alarm Controller.
 
The FC410DIM monitors the status of detectors and wiring to detectors and signals detector and wiring status back to the Controller.
 
The FC410DIM requires a 24Vdc power supply.
 
Product order code: 555.800.712
 
Beam Detector Interface Module
 


 
The FC410BDM Beam Detector Interface Module is designed to power and interface one FIRERAY 50/100/3000/5000 Beam Detector to the FireClass Digital Addressable Loop.
 
The FC410BDM monitors the Fire and Fault contacts and also monitors for open and short circuits on the connections between the interface and the beam detector.
 
For remote siting of the FIRERAY detector an optional BTM800 Terminal Module can be used.
 
Product order code: 555.800.766 
 
Beam Detector Module
 


 
In many cases it will be necessary to site the FC410BDM Beam Detector Module some distance from the beam detector itself. To minimize and simplify wiring in such cases an optional unit, the BTM800 beam termination module is available.
 
The BTM800 is also housed in a standard double gang ancillary cover and has all the connections and components required to minimize installation time.
 
Product order code: 555.800.067
 
Relay Interface Module
 


 
The FC410RIM Relay Interface Module provides one volt-free relay changeover contact on a latching relay. The relay is controlled by a command sent from the FireClass fire controller via the addressable loop.
 
The relay state (activated, deactivated or stuck) is returned to the controller as confirmation.
 
Product order code: 568.800.703
 
Sounder Notification Module
 


 
The FC410SNM Sounder Notification Module is designed to provide an output, in response to a command signaled from a controller, to activate a number of polarized and suppressed sounders. The sounders are powered from an independent power supply and the module is capable of passing up to a maximum of 2A (e.g., 24V dc 50mA company sounders or a mixture of different current rated sounders not exceeding a maximum current of 2A).
 
Product order code: 577.800.705
 
Sounder Booster Module
 


 
The SB520 sounder booster module enables the FC410SNM to drive circuits with higher currents whilst maintaining the reverse polarity integrity line monitoring. It is non-addressable and requires a local 24 V DC supply to drive a single circuit of polarized and suppressed sounders.
 
Product order code: 577.001.023
 
High Voltage Relay Interface
 


 
The HVR800 High Voltage Relay Interface is a non-addressable multi-voltage relay module (operating from 24V DC, 24V AC, 120V ac and 240V AC).
 
The encapsulated HVR800 provides a 10 amp volt-free contact that can be used to extend the contact ratings of FC410RIM Addressable Relay Module applications.
 
A maximum of four HVR800s can be individually driven and controlled by an FC410MIO Small Addressable Multi-Input/Output module if all HVR800s are powered by 120V ac or 240V AC. For ac operation, no external dc power supply unit is required to operate the relay. When used to switch 24V DC, the HVR800 must be provided with an external 24V DC supply which should be switched through the clean relay contacts of an FC410MIO or FC410RIM.
 
Product order code: 568.800.004
 
Single Input/Output Module
 


 
The FC410SIO Single Input/Output Module is designed to provide a monitored open collector input and a volt free relay changeover output. FC410SIO can switch up to 2 A @ 24 VDC.
 
Product order code: 555.800.763
 
Multi I/O Module
 


 
The FC410MIO Multi I/O Module has three inputs and two outputs from latching relays. The inputs can monitor fire contacts such as extinguishing system control, ventilation control, fire door control etc.
 
The two relays outputs provide volt-free relay changeover contacts.
 
Product order code: 555.800.765
 
Quad Monitored Output Module
 


 
The FC410QMO comprises of four monitored relay outputs that are suitable for 24Vdc sounders. The outputs are monitored for short and open circuit faults.
 
Product order code: 555.800.770
 
Quad Input/Output Module
 


 
The FC410QIO Quad Input/Output Module is designed to provide four monitored digital inputs and four potential free relay changeover outputs.The outputs can be connected to an Auxiliary Voltage source and its voltage can be monitored.
 
The FC410QIO has an integral FireClass loop isolator. When a section of the loop adjacent is shorted, the isolator trips, isolating the shorted section, then the yellow LED illuminates. This status remains until the short is removed. The FC410QIO must be fitted in a control enclosure or any distributor enclosure. The FC410QIO will be preferably mounted via a DIN rail. Alternatively, it can be directly fixed on the rear side of the enclosure. The digital input monitoring and isolator functions are both configurable. Furthermore, all outputs can be connected to the HVR800 which allows switching to high power galvanic isolated loads.
 
Product order code: 555.800.771
 
Quad Relay Module
 


 
The FC410QRM Quad Relay Module is designed to provide four potential free relay changeover outputs. The outputs are monitored with parallel contacts of the relays. The outputs can be connected to an Auxiliary Voltage source and its voltage can be monitored. The FC410QRM has an integral FireClass loop isolator. When a section of the loop adjacent is shorted, the isolator trips, isolating the shorted section, and illuminating a yellow LED. This status remains until the short is removed.
 
The FC410QRM must be fitted in a control enclosure or any distributor enclosure. The FC410QRM will preferably be mounted via a DIN rail. Alternatively, it can be directly fixed on the rear side of the enclosure. Furthermore, all outputs are configurable to the HVR - mode (High Voltage Relay), which allows connection of up to four HVR800 modules for switching e.g. 240V loads galvanic isolated.
 
Product order code: 555.800.773
 
Line Isolator Module
 


 
The FC410LI Line Isolator Module is designed to be used on the FireClass addressable controller loop. It monitors the line condition and when detecting a short circuit will isolate the affected section whilst allowing the rest of the loop to function normally. The purpose of the FC410LI Line Isolator Module is to ensure that, on a looped addressable system, no short circuit fault can disable more detection devices than would be lost on a conventional non-addressable fire circuit.
 
Product order code: 545.800.704
 
Door Control Module
 


 
When activated, either by a fire signal or by a fault or isolation within the fire door zone, the FC410TSM will interrupt the supply to the door holders and the doors under control of the module will close. The module has the provision to monitor a contact to report to the fire controller ifthe door fails to close. The module also includes a built-in line isolator.
 
Product order code: 555.800.769
 





  • Documents
  • Additional Information
Document TitleDocument Type
DoP-2015-4017_iss03_FC410MIOApprovals
DoP-2015-4018_iss03_FC410RIMApprovals
DoP-2015-4018(ESP)_iss03_FC410RIMApprovals
DoP-2015-4019_iss03_FC410DIMApprovals
DoP-2015-4020_iss03_FC410CIMApprovals
DoP-2015-4020(ESP)_iss03_FC410CIMApprovals
DoP-2015-4021_iss03_FC410BDMApprovals
DoP-2015-4022_iss03_FC410MIMApprovals
DoP-2015-4034(POL)_iss03_DDM800_FC410DDMApprovals
DoP-2015-4034_iss03_DDM800_FC410DDMApprovals
DoP-2015-4171(POL)_iss03_TSM800_FC410TSMApprovals
DoP-2015-4171_iss03_TSM800_FC410TSMApprovals
DoC1611_Iss3_FC-IO-ModulesApprovals
CPR Declaration of Performance FC410MIM 555.800.701Approvals
CPR Declaration of Performance FC410DDM Input Module 577.800.706Approvals
CPR Declaration of Performance FC410DIM 555.800.712Approvals
CPR Declaration of Performance FC410BDM 555.800.766Approvals
CPR Declaration of Performance FC410RIM 568.800.703Approvals
CPR Declaration of Performance FC410SNM 577.800.705Approvals
CPR Declaration of Performance FC410SIO 555.800.763Approvals
CPR Declaration of Performance FC410MIO 555.800.765 Approvals
CPR Declaration of Performance FC410QMO 555.800.770Approvals
CPR Declaration of Performance FC410QIO 555.800.771Approvals
CPR Declaration of Performance FC410QRM 555.800.773Approvals
CPR Declaration of Performance FC410LI 545.800.704Approvals
BRE_2831-CPR-F0286_FC410LPBS-R_Issue1Approvals
BRE_2831-CPR-F0287_FC410LPBS-W_Issue1Approvals
BRE_2831-CPR-F0288_FC410LPBS_LP_Issue1Approvals
BRE_2831-CPR-F0289_FC430LPBSB_LP_Issue1Approvals
BRE_2831-CPR-F0305_FC430SB_Issue1Approvals
BRE_2831-CPR-F0550_FireClass_64-4_Issue1Approvals
BRE_2831-CPR-F0551_FireClass_240-2_Issue1Approvals
BRE_2831-CPR-F0553_FireClass_32RA_Issue1Approvals
BRE_2831-CPR-F0554_FireClass_64RA_Issue1Approvals
BRE_2831-CPR-F0555_FireClass_240RA_Issue1Approvals
BRE_2831-CPR-F1003_601SBD_Issue1Approvals
BRE_2831-CPR-F1004_601SB_Issue1Approvals
BRE_2831-CPR-F1005_601F_Issue1Approvals
BRE_2831-CPR-F1011_611H-F_Issue1Approvals
BRE_2831-CPR-F1012_DDM800_Issue1Approvals
BRE_2831-CPR-F1363_LPSY800_FC410LPSYR_Issue2Approvals
BRE_2831-CPR-F1630_HVR800_Issue1Approvals
BRE_2831-CPR-F1631_CIM800_Issue1Approvals
BRE_2831-CPR-F1632_DIM800_Issue1Approvals
BRE_2831-CPR-F1633_RIM800_Issue1Approvals
BRE_2831-CPR-F1634_MIM800_Issue1Approvals
BRE_2831-CPR-F1635_SNM800_Issue1Approvals
BRE_2831-CPR-F1637_MIO800_Issue1Approvals
BRE_2831-CPR-F1638_BDM800_Issue1Approvals
BRE_2831-CPR-F1639_DDM800_Issue1Approvals
BRE LPCB Certificate of Conformity FC410CIMApprovals
BRE LPCB Certificate of Conformity FC410MIMApprovals
BRE LPCB Certificate of Conformity FC410DDMApprovals
BRE LPCB Certificate of Conformity FC410DIMApprovals
BRE LPCB Certificate of Conformity FC410BDMApprovals
BRE LPCB Certificate of Conformity FC410RIMApprovals
BRE LPCB Certificate of Conformity FC410MIOApprovals
FNO_IO-1082_21_CIM800_FC410CIM_16-10-2024Approvals
FNO_IO-1083_21_FC410QIO_QRM_QMO_4-8-2026Approvals
FNO_IO-1085_21_MIM800_FC410MIM_16-10-2024Approvals
FNO_IO-1086_21_BDM800_FC410BDM_16-10-2024Approvals
FNO_IO-1087_21_DIM800_FC410DIM_16-10-2024Approvals
FNO_IO-1088_21_SIO800_FC410SIO_14-11-2026Approvals
FNO_IO-1089_21_DDM800_FC410DDM_16-10-2024Approvals
FNO_IO-1090_21_MIO800_FC410MIO_16-10-2024Approvals
FNO_IO-1091_21_RIM800_FC410RIM_16-10-2024Approvals
FNO_IO-1093_21_SNM800_FC410SNM_16-10-2024Approvals
FNO_IO-1094_21_TSM800_FC410TSM_04-08-2024Approvals
FNO_KSI-1025_21_FC410LI_04-08-2023Approvals
VdS_G221021_FC410SIO_26-01-2024Approvals
Vds Certificate of Approval FC410SIOApprovals
VDS Certificate of Approval FC410QMOApprovals
VdS Certificate of Approval FC410QIOApprovals
VdS Certificate of Approval FC410QRMApprovals
Vds Certificate of Approval FC410LIApprovals
EN54-13 FIRECLASS System CertificateApprovals
Addressable Loop Modules Data Sheets
FC410MIM Schematic DrawingSchematic Drawings
FC410DIM Schematic DrawingSchematic Drawings
FC410BDM Schematic DrawingSchematic Drawings
FC410RIM Schematic DrawingSchematic Drawings
FC410SNM Schematic DrawingSchematic Drawings
HVR800 Schematic DrawingSchematic Drawings
FC410SIO Schematic DrawingSchematic Drawings
FC410MIO Schematic DrawingSchematic Drawings
FC410QMO Schematic DrawingSchematic Drawings
FC410QIO Schematic DrawingSchematic Drawings
FC410QRM Schematic DrawingSchematic Drawings
FC410LI Schematic DrawingSchematic Drawings
FC410QIO Addressable Quad I/O Module BIM Objects
FC410BDM Addressable Beam Detector ModuleBIM Objects
FC410CIM Addressable Contact Input Module BIM Objects
FC410DDM Addressable Fire&Gas Detection Module BIM Objects
FC410DIM Addressable Detector Interface Module BIM Objects
FC410LI Addressable Line Isolator Module BIM Objects
FC410MIM Addressable Mini input Module BIM Objects
FC410MIO Addressable Multi I/O ModuleBIM Objects
FC410QMO Addressable Quad monitored output Module BIM Objects
FC410QRM Addressable Quad Relay Module BIM Objects
FC410RIM Relay inteface ModuleBIM Objects
FC410SIO Addressable Single I/O Module BIM Objects
FC410SNM Addressable Sounder Output Module BIM Objects
FC410TSM Addressable Door Control Module BIM Objects
FireClass FC410CIM Addressable Contact Input Module Specification SheetTechnical Documentation
FireClass FC410MIM Mini Input module Specification SheetTechnical Documentation
FireClass FC410DIM Smoke Alarm Detector Input Module Specification SheetTechnical Documentation
FireClass FC410BDM Beam Detector Module Specification SheetTechnical Documentation
FireClass FC410RIM Relay Interface Module Specification SheetTechnical Documentation
FireClass FC410SNM Fire Alarm Sounder Notification Module Specification SheetTechnical Documentation
FireClass FC410SIO Single Input Output Module Specification SheetTechnical Documentation
FireClass FC410MIO Multi Input Output IO Module Specification SheetTechnical Documentation
FireClass FC410QIO Quad Input Output Module Fixing InstructionsTechnical Documentation
FireClass FC410QRM Quad Relay Module Fixing InstructionsTechnical Documentation
FireClass FC410MIM Mini input module - Fixing InstructionsTechnical Documentation
FireClass FC410MIO Small addressable multi I/O module - Fixing InstructionsTechnical Documentation
FireClass FC410SIO Single Input/Output Module - Fixing InstructionsTechnical Documentation
FireClass FC410BDM Beam detector module - Fixing InstructionsTechnical Documentation
FireClass FC410CIM Contact input module - Fixing InstructionsTechnical Documentation
FireClass FC410DIM Detector input module - Fixing InstructionsTechnical Documentation
FireClass FC410SNM Sounder notification module - Fixing InstructionsTechnical Documentation
FireClass FC410DDM- Universal Fire and Gas Detector ModuleTechnical Documentation
FireClass FC410LI Line Isolator Module Fixing InstructionsTechnical Documentation
FireClass FC410TSM Door Control Module Fixing InstructionsTechnical Documentation
FireClass Quad Modules Product InformationTechnical Documentation
FireClass FC410QMO Quad Monitored Output Module Fixing InstructionsApprovals

Part & Order Information

Product Order Codes

 
545.800.704 FC410LI LINE ISOLATOR MODULE
555.800.067 BTM800 MODULE C/W ENCLOSURE
555.800.701 FC410MIM MINI INPUT MODULE
555.800.702 FC410CIM CONTACT I/P MODULE
555.800.712 FC410DIM DETECTOR I/P MODULE
555.800.763 FC410SIO SINGLE I/O MODULE 
555.800.765 FC410MIO MULTI I/O MODULE
555.800.766 FC410BDM BEAM DETECTOR MODULE 
555.800.769 FC410TSM DOOR CONTROL MODULE
555.800.770 FC410QMO QUAD MONITORED O/P
555.800.771 FC410QIO QUAD I/O MODULE 
555.800.773 FC410QRM QUAD RELAY MODULE 
568.800.004 HVR800 HIGH VOLTAGE RELAY 
568.800.703 FC410RIM RELAY I/F MODULE
577.001.023 SB520 SOUNDER BOOSTER MODULE   
577.800.705 FC410SNM SOUNDER OUTPUT MODULE
577.800.706 FC410DDM FIRE &
GAS DET MOD

You are not authorized to view this document. Please Sign-in
Skip to main content
Product Detail